Installation Tips for Pressure-Sensitive Elastoform Products
December 23, 2019

STORAGE: Heat exposure is what causes Pressure-Sensitive Elastoform Flashing® (PSEF) to cure on the roof after installation, so storing all your PSEF in a cool place will maximize its shelf life. Carlisle performed an experiment where Sure-White® Corners were refrigerated for 18 months and they were still uncured and usable. Pretty "cool" for a product with a 6-month shelf life!

HEAT: Want to make your PSEF easy to work with? Use a heat gun to warm the flashing prior to installation in colder weather. Always heat Sure-White PSEF even in the warmer months. Rule of thumb; store cool and install warm!

INSTALLATION: Speaking of forming corners, the PSEF stretches and forms better when the elongated diamond pattern is installed parallel to the deck membrane. Additionally, it helps to use the poly film as a separator when folding the corner in half to prevent the exposed tape edges from sticking to each other.

POURABLE SEALER POCKETS: One of the biggest mistakes Carlisle encounters with Pourable Sealer Pockets is improperly applied or missing primer. It is very important to prime the flashing that is turned down into the pocket, as well as the flashing on the top rim of the pocket. Primer is necessary to achieve a long-term bond between Pourable Sealer and PSEF. If separation is present, it's likely that primer application was missed. It is also important and necessary to thoroughly clean and prime penetrations prior to filling pockets with pourable sealer.

OUTSIDE CORNERS: Double-wrapping outside corners is a great idea on ballasted systems, especially if the base membrane isn't cut perfectly tight to the curb. PSEF needs to have a solid surface beneath it for long-term performance. If an additional layer of PSEF is installed to eliminate voids at outside corners, the corner flashing will be better able to withstand movement from expansion/contraction forces and will be less likely to develop a hole than if a single layer of PSEF is used.

LAP SEALANT: All PSEF requires Lap Sealant to be applied and feathered over the entire splice edge.

Please contact your Regional Manager with questions



    Ron Goodman
    EPDM Product Manager
    Product Marketing
    ron.goodman@carlisleccm.com
February 25, 2020
Dual Tanks Cold Weather Application Tips

Proper material temperatures are imperative to ensure that adhesive products deliver the highest level of performance. When applying adhesive products below the manufacturer’s recommended application temperatures, application speed and performance can be drastically affected. To help address material temperature issues, Carlisle has recently announced the availability of heated blankets and temperature sensing nozzle technology. Flexible FAST reaches its maximum performance when the material temperature at the time of installation is 70°F or rising. When temperatures fall below 70°F, urethane adhesives can experience mixture ratio issues that could create application issues. To help address material temperatures during winter applications, the use of hot boxes and power blankets are recommended to ensure the adhesive remains at 70°F or above at the time of application. For more information regarding heated blankets, click here or visit the website for one of Carlisle equipment partners: PowerBlanket 4C's Spray Equipment Panther East In addition to heated blankets, Carlisle has also made advancements to delivery systems to help applicators identify when an adhesive product is too cold. In January 2020, Carlisle introduced Temperature Warning Tips for Flexible FAST Dual Tanks. These tips make it easy to apply polyurethane adhesives properly. Carlisle’s Temperature Warning Tips provide the applicator with a visual cue to easily identify if the material is too cold during application: Nozzle turns BLUE when adhesive temperature is below the required 70°F. Nozzle will be CLEAR when adhesive is spraying at optimal temperature. Compression seal added to create a tighter fit between the gun and tip. This helps eliminate adhesive leaks. For more information, please contact your manufacturer's representative.

Read This Post
February 11, 2020
Code-Required Minimum R-Values

Over the past 10 years, there has been a shift in minimum required R-values. The 2015 International Energy Conservation Code (IECC) is the driving force behind this movement. More than 20 states have adopted the 2015 IECC, or a portion of its provisions, as their statewide energy code. See the chart below for minimum R-values per climate zone. Since 2009, the roofing industry has seen an R-10 increase in the majority of the states. The total minimum insulation thickness has increased from 3.5" (R-20) to 5.2" (R-30) in parts of over 40 states. The map below can help you identify climate zones within your state. Climate zones 4 through 8 have experienced an R-10 increase. Additional resources are provided below to help you determine the applicable energy code and its associated minimum R-value requirements in a given state or local jurisdiction.    1. Minimum Insulation R-value Requirements: Non-Residential, Above Roof Deck    2. The Building Codes Assistance Project For more information on R-value requirements, please contact Brandon Reynolds at brandon.reynolds@carlisleccm.com

Read This Post
January 28, 2020
Polyiso Storage, Handling, and Application Guidelines

It is well known that moisture is detrimental to roof system performance. Wet insulation can lead to several issues including mold, reduced membrane adhesion, and ultimately roof system failure during wind events. Because wet polyiso must be removed and replaced, watertight tie-ins are essential every night. But let's take a step backwards and look at overall polyiso storage before and during installation. An appropriate understanding of storage, handling, and application will result in a properly constructed roof system. Material delivery should be carefully coordinated with the roof installation schedule to minimize outdoor storage. However, short-term outdoor storage can be necessary at times. When storing polyiso outdoors, bundles should not be stored directly on the ground. If possible, they should be stored over a finished surface rather than dirt or grass. Bundles should be covered with a waterproof cover and secured to prevent wind displacement. Exercise care when handling polyiso to prevent breaking or crushing the edges and surfaces. Polyiso should always be installed on dry roof decks and in dry conditions. Apply only as much polyiso as can be covered by completed roofing the same day. Roof surface protection (plywood) should be used in areas where storage and staging are planned to reduce direct, excessive traffic. Tips: Place bundles on pallets or included feet over a finished surface such as gravel, pavement, or concrete. Remove polyiso bundles from trucks with proper equipment. Do not push bundles off the edge of a truck or "roll" a pallet across the roof deck. Follow Carlisle’s requirements regarding product application to ensure adequate performance of the roofing system. For more information, please contact your manufacturer's representative.

Read This Post
X
Email to your Colleagues >
Separate multiple emails with a comma or semicolon.
Copy Me


Please log in to share this item by email.
Add to a Collection >
Please log in to share this item to your collections.
Private
Private Collection (change)

Loading...
Invite user by email:
User Invited. Invite another
User Invite Failed, try again.
X
Visibility Options
Public Collection
Anyone with a link can view. No sign-in required.
Private Collection
Only people explictly granted permission can access. Sign-in required.
X

You are now working in your copied collection
Okay