Electronic Leak Detection for Roofing Systems
October 16, 2019
A building’s roofing system separates the damaging outdoor environment from the valuable interior contents. To be effective, it must be watertight. Although roof systems are inspected and sometimes flood tested prior to warranty issuance, small, difficult-to-see breaches in the membrane system can go unnoticed until damaging water leaks occur inside the building. Moreover, once a leak has developed it can be extremely difficult to locate the leak and perform the necessary repair, especially when overburden materials are installed.
Enter Electronic Leak Detection, otherwise known as ELD. ELD systems have been around for 20+ years and are gaining popularity due to some revolutionary new products that have expanded testing capabilities. ELD systems come in two main varieties: low-voltage and high-voltage, with low-voltage being the most common. ELD systems work by creating an electrical potential difference between a non-conductive roof membrane and a grounded conductive structural deck or substrate. Testing is performed by applying water, which is conductive, to the surface of the roof membrane. The roof membrane will isolate the potential electrical difference between the deck and the water, but when a breach is present, the water will create an electrical connection to the grounded deck, pinpointing the exact leak location to the testing technician. A major benefit of ELD testing is that it can be performed at any time, even after overburden materials are installed.

For ELD systems to be effective, a conductive substrate must be present directly below the membrane’s surface. Due to this requirement, membrane choice and application method can be limited.
Two ELD companies that Carlisle has experience with are International Leak Detection (ILD) and Detec Systems. Products from either of these companies are permitted for use in a Carlisle warranted roof system but are not covered in the Carlisle warranty.

ILD has been around since 2001 and promotes a conductive mesh that must be installed directly below the membrane for accurate testing of membrane systems over non-conductive decks. Due to the design of the conductive mesh, it is only acceptable for use under thermoplastic FleeceBACK® membranes adhered with FAST™ or Flexible FAST Adhesive.

Detec Systems promotes a conductive primer called TruGround® that is roller-applied over the top layer of insulation, prior to adhesive application. Once dried, the membrane system can be installed as usual. TruGround conductive primer expands ELD testing capabilities, as it is suitable for use with bareback membranes and even black EPDM, which historically has not been compatible with ELD testing. Carlisle SynTec Systems has secured FM approvals for Detec’s TruGround in a number of different roofing assemblies. Those assemblies include:

EPDM and TPO with CAV-GRIP® III adhesive over SecurShield®, SecurShield HD, DensDeck® Prime, and SECUROCK®.
PVC with Low-VOC Bonding Adhesive over InsulBase®, SecurShield, SecurShield HD, and SecurShield HD Plus.

 Contact Chris Kann with questions regarding ELD systems.
March 4, 2020
ENERGY STAR Roofing Program Phaseout

The ENERGY STAR® Roofing Program will be phased out by June 1, 2022 The U.S. Environmental Protection Agency (EPA) has announced they are sunsetting the ENERGY STAR reflective roof program effective June 1, 2022. Program Partners must cease production of printed or electronic marketing material using the ENERGY STAR mark by June 1, 2021. All references to ENERGY STAR must cease by June 1, 2022. As a leader in the commercial roofing industry and the largest manufacturer of reflective and non-reflective roofing materials, Carlisle Construction Materials supports this change, as it eliminates one source of confusion regarding energy efficient roof design. As a rule of thumb for energy efficiency, reflective roofs are best suited for cooling-dominated climates where buildings' air conditioning demands or costs exceed their heating demands – typically, southern markets in ASHRAE Zones 1, 2, and parts of 3. In heating-dominated climates, a non-reflective roof covering is ideal to reduce heating costs (and the burning of fossil fuels) as well to as mitigate the risk of condensation-related issues within the roofing assembly. Carlisle continues to advocate for careful selection of complete roofing systems based on required performance attributes and considering the building's design, intended use, location, and climatic conditions. Additional Resources For more information on roof condensation, reference the November 2012 Design Advisory on how to avoid condensation issues from occupancy- or construction-generated moisture. November 2012 Design Advisory For more information on the condensation risks of cool roofs, check out this short animation. Condensation Risks of Cool Roofs For further reading, visit the Carlisle SynTec website for a white paper on Mechanically Attached Roof Systems in Cold Climate Zones. White Paper Contact Craig Tyler at Craig.Tyler@CarlisleCCM.com with questions.

Read This Post
February 19, 2020
FM’s VSH Testing – Very Severe Hail

FM Global, a leading commercial building insurer, and its code-approved testing agency subsidiary, FM Approvals, have created a Very Severe Hail (VSH) impact resistance classification that could affect design professionals. FM Global Guidelines Traditionally, FM Global has recommended its insured building owners use moderate hail (MH) and severe hail (SH) classified roof systems for buildings located in areas FM Global considers to be susceptible to moderate or severe hail impacts. FM Loss Prevention Data Sheet 1-34 ("Hail Damage") provides a map identifying these regions. In recent years, the insurance industry in the United States has seen an uptick in losses from hail in terms of the number of claims experienced and costs of those claims. A majority of the hail damage occurs to roof systems and other rooftop components. In the latest version of FM 1-34 (April 2019), FM Global identified a new VSH region encompassing Oklahoma, Kansas, Nebraska, South Dakota, most of Texas, and parts of Montana, North Dakota, Minnesota, Iowa, Missouri, Arkansas, Wyoming, Colorado, and New Mexico.  Per FM Global, this area was classified as a VSH region based on data from the National Oceanic and Atmospheric Administration's National Weather Service and National Center for Environmental Protection's Storm Prediction Center. This data shows a concentration of reports of hail greater than 2 inches in diameter in this geographical region. Until recently, FM Approvals did not have VSH-classified roof systems available to satisfy its recommendation in the VSH region. In the interim, FM 1-34 recommended using assemblies tested to a Class 4 rating using FM 4473 ("Specification Test Standard for Impact Resistance Testing of Rigid Roofing Materials by Impacting with Freezer Ice Balls"). FM 1-34 indicates aggregate- and paver-ballasted roof systems can be substituted for MH- and SH-classified roof systems in the MH and SH regions. However, FM Global restricts the use of aggregate-ballasted roof systems on buildings taller than 150 feet, or in areas where the design wind speed is 100 miles per hour or greater. FM has indicated only paver-surfaced roof systems can be substituted for a VSH-classified roof system. FM 1-34 also contains recommendations for skylights, rooftop HVAC equipment, and other critical outdoor equipment in the MH, SH, and VSH regions. Hail Classifications FM Approvals traditionally has tested and classified membrane roof systems for MH and SH impact resistances using FM 4470 ("Approval Standard for Single-Ply, Polymer-Modified Bitumen Sheet, Built-Up Roofs (BUR) and Liquid Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction). This is the same test method on which many FM Approvals roof system classifications are based. Using FM 4470's procedure, MH-classified roof systems withstand a 2-inch-diameter steel ball weighing 1.19 pounds dropped from a height of 81 inches in a section of tubing. This results in an impact energy of about 8 foot-pounds (ft-lbs.) on the surface of the roof system test specimen. SH-classified roof systems withstand the same 2-inch-diameter steel ball dropped from a height of 141.5 inches, resulting in an impact energy of about 14 ft-lbs. on the surface of the roof system test specimen. FM Approvals recently updated its impact-resistance test method to include testing for the VSH classification. The new testing involves propelling 2-inch-diameter preformed ice balls at roof system test specimens using an ice ball launcher. The ice balls are propelled at 152 to 160 feet per second, resulting in an impact energy of 53 to 58 ft-lbs. on the surface of the roof system test specimen. With these higher test standards, new materials and assemblies are being developed and tested to meet the new ratings. Carlisle has introduced a new coverboard, EcoStorm, that can achieve the VSH rating. Carlisle currently has 133 approved VSH approved assemblies. For more information on EcoStorm VSH Coverboard, click here. Contact Brian Emert at Brian.Emert@CarlisleCCM.com with further questions.

Read This Post
February 5, 2020
Spray Foam for Walls – The Perfect Wall

The challenge with every design is making sure that it will work in a specific environment. Through understanding the principles of a "perfect wall" - one which contains a water-shedding layer, an air control layer, a vapor control layer, and a thermal control layer - we can generate a wall solution that will work in every environment. The control layers are listed in order of importance. All are important, but not equally important. The ranking comes from historic experience and the underlying physics. Controlling water in the liquid form (rain and ground water) has been the focus of architects for generations. Controlling air is a much more recent focus - less than a century. The corollary, however, is too often true for many in the industry. There should be no doubt, the water control layer is much more important than the air control layer. Controlling vapor is even more recent - only a generation or two. Air movement transports significantly more water in vapor form than does vapor diffusion and therefore air control is more important than the control of molecular water vapor. "Air barriers" are more important than "vapor barriers". Thermal control dates back millennia - but getting it wrong has rarely led to durability failures. The thermal control layer failures have been typically limited to comfort issues and operating cost issues. Hence, thermal control layers are listed last on the control layer "priority" list. In the last decade we have been successful at combining the water control layer, air control layer, and vapor control layer into a single layer that can be a film, coating, membrane, or sheet goods. We have also had good success with wrapping the exterior of a building with all of these control layers and then enclosing those control layers with the fourth control layer - the thermal control layer. This configuration, with the thermal control layer outboard of the water, air, and vapor control layers, allows the assembly to be constructed in all climate zones: cold, mixed, hot and humid, or dry. Even better, this configuration allows this assembly to enclose virtually all interior environments in all climate zones: offices, commercial, residential, institutional, pools, museums, art galleries, and data processing centers. The sole exception being refrigerated buildings and cold storage facilities. In such assemblies the location of the thermal control layer is "flipped" with the other control layers - the thermal control layer now becomes located on the interior of the other three control layers. Utilizing spray foam technology, you can create the "perfect wall" with spray polyurethane (SPF) which meets; Water Control Layer - SPF is inherently moisture resistant. Air Control Layer - SPF has an Air Impermeability of <0.02 (L/s/m2) @ 1 inch of mercury. Vapor Control Layer - SPF has a water vapor permeability of 1.4 perm @ 1 inch of mercury. Thermal Control Layer - SPF has an R-Value per inch of 6.9. This also allows for thinner walls and continuous insulation without thermal breaks. Visit the Carlisle Spray Foam Insulation website at carlislesfi.com for more information on how your next project could utilize spray foam insulation as a "perfect wall" solution. Contact Brian Emert at Brian.Emert@CarlisleCCM.com with further questions.

Read This Post
X
Email to your Colleagues >
Separate multiple emails with a comma or semicolon.
Copy Me


Please log in to share this item by email.
Add to a Collection >
Please log in to share this item to your collections.
Private
Private Collection (change)

Loading...
Invite user by email:
User Invited. Invite another
User Invite Failed, try again.
X
Visibility Options
Public Collection
Anyone with a link can view. No sign-in required.
Private Collection
Only people explictly granted permission can access. Sign-in required.
X

You are now working in your copied collection
Okay